Fluke

Fluke ii500/FPC3 acoustic imager with LeakQ™ and three-year Premium Care, 2 to 52 kHz, 164′

Fluke ii500/FPC3 acoustic imager with LeakQ™. 2 to 52 kHz band to 164' (50 m), supplied with three-year Premium Care Standard.

$14,641.00 USD

Prices in USD, shipping not included.
Shipping cost, lead time and availability are confirmed in your quotation.

TSA SKU
TSA_71724185

Specifications

  • Acoustic imager for maintenance teams that detects, locates and prioritizes gas leaks in compressed air, gas, steam and vacuum systems
  • Same imager as the ii500, supplied with three years of Fluke Premium Care Standard
  • Blends a live SoundMap™ with a visual image; LeakQ™ mode gives on-device leak size and cost estimates (scale 1 to 10)
  • Also used for electrical inspections, mechanical anomaly detection, energy audits, preventive maintenance and building diagnostics
  • Annotation with photo notes, asset identifiers, text notes, follow-up actions and QR codes; FlukeConnect™ reporting software integration
  • Frequency band: 2 to 52 kHz; detection range 1.6 to >164' (0.5 to >50 m); FOV 63° ±5°; 25 FPS
  • Display: 7" (17.7 cm) capacitive touchscreen, 1280 x 800, sunlight readable; visible-light camera 0.3 MP
  • Storage: 20 GB (>5000 pictures / >999 videos); video up to 5 minutes; USB-C
  • Safety and protection: IEC 61010-1 pollution degree 2; IP40
  • Operating temperature: 14 to 113°F (-10 to 45°C); relative humidity 10 to 95% non-condensing
  • Battery: rechargeable, field-replaceable Li-ion; 6 hours operation, 3 hours charging with external bay charger
  • Dimensions: 7.3 x 12.7 x 2.7" (186 x 322 x 68 mm); weight 4.6 lbs (2.1 kg) with battery
  • In the box: acoustic imager, USB-C cable, array sensor cover

Specifications are provided by the manufacturer and may change. Please confirm the exact model in your quote request.

More in Acoustic Imaging Cameras